2
Measurement
FZ3 Processing Items List Manual
Gravity and Area
169
measurements can be made correctly.
5.
Set up the judgement condition.
Note
●
The values beside each item are measurement results of the displayed image.Take these values into
consideration to determine the upper and lower limits.
Setting item
Set value
Description
Area
0 to 999999999.9999
Specify the area to be judged as OK.
Gravity X
-99999.9999 to
99999.9999
Specify the range of X-axis shifting that is judged to be
OK.
Gravity Y
-99999.9999 to
99999.9999
Specify the range of Y-axis shifting that is judged to be
OK.
Output Parameters (Gravity and Area)
Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
●
After setting up the measurement parameters, changing the output parameters will cause measurement results
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
2.
Specify each of the following items.
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...