![background image](http://html.mh-extra.com/html/omron/xpectia-fz3/xpectia-fz3_user-manual_1633321288.webp)
3
Compensate
image
286
Trapezoidal Cor
FZ3 Processing Items List Manual
Trapezoidal Cor
This is a processing item for just FZ3-H
series high grade controllers.
If measurement is performed with the measurement object tilted or the camera tilted, the input image is
converted to orthogonal coordinates.
Used in the Following Case
●
Processing a trapezoidal image shot tilted to make it easier to inspect
Important
●
When FZ3-H
series dedicated processing items are used, processing is carried out that reduces the
processing time from the second time on. Therefore, when measuring the same image, the processing for the
first time after the controller is started up may be longer than the processing time from the second time on.
Conversion Method (Trapezoidal Cor)
Set the input image conversion method.
1.
In the Item Tab area, tap [Conv. method].
When making a new setting, you do not need to tap [Conv. method].
2.
As necessary, set the parameters.
Acesst 1.0 6251194