6
Output
result
416
Parallel Data Output
FZ3 Processing Items List Manual
2.
In the list, tap the output No. for which the expression is to be set.
The selected output No. is displayed under the list.
3.
Tap [...] for the expression and set the expression.
Reference:
Layout of Setting Expression Window (p.333)
4.
Input an explanation of the expression in "Comment" as necessary.
5.
Repeat steps Reference:
2(p.416) to Reference:
4(p.416) and set up the output contents for each output number.
Output Format (Parallel Data Output)
1.
In the Item Tab area, tap [Output format] and select [Format] in the output setting area.
Set value
[factory
default]
Description
[Binary]
Data is output as 2's complement binary data.
For 2's complement
Reference:
See "User's Manual", "Terminology Explanations" (p.309)
BCD
Data is output expressing 1 digit with 4 bits and expressing 3-digit integers and signs
with 16 bits.
●
15 to 12 bits
Sign. (positive: 0000, negative: 1111)
●
11 to 0 bits
Data is expressed with 1 digit for every 4 bits and is expressed from the
hundreds place (bits 11 - 8: 3rd digit) to the ones place (bits 3 - 0: 1st digit).
2.
Tap [OK].
The settings are finalized.
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...