1
Input
image
30
Camera Image Input
FZ3 Processing Items List Manual
Origin
[Upperleft],
Lowerleft, Center
Select where the origin of the actual coordinates will be.
Magnification
0.00001 to
9.99999
Specify the ratio of 1 pixel to the actual dimensions.
4.
Tap [Generate calibration parameters].
The calibration parameters will be generated.
View Calibration Parameters
View the set calibration data.
1.
In the Item Tab area, tap [Calibration].
2.
In the "Calibration parameter" area, confirm the calibration data.
Item
Set value
Description
A
Calculation value
These are calibration conversion values. Camera coordinates are
converted to actual coordinates based on these values. The
conversion formulas for actual coordinates are as follows:
●
(X, Y): Measurement point (camera coordinates), Unit: pix
●
(X', Y'): Conversion point (actual coordinates)
X'=A x X + B x Y + C
Y'=D x X + E x Y + F
B
Calculation value
C
Calculation value
D
Calculation value
E
Calculation value
F
Calculation value
Acesst 1.0 6251194