2
Measurement
FZ3 Processing Items List Manual
Scan Edge Position
137
Note
Reference position usage method: Measuring the distance from a specific position
●
Positional deviation can be inspected by calculating the difference between the reference position and the
measured position with an expression.
After changing the reference position to any desired position, changing the measurement region will
automatically change it back to the default position.
1.
In the Item Tab area, tap [Ref. position].
In the Image Display area, the current reference position will be displayed as the crosshair
cursor.
2.
Tap the position to be set as the reference position.
3.
If necessary, finely adjust with numeric input and the arrow buttons.
To remeasure on the displayed image and set the reference position, tap [Measure ref.].
Measurement Parameters (Scan Edge Position)
Measurement parameters can be changed as needed to address unstable measurement
results.Normally, the factory default value will be used.
After changing a setting, check whether measurement can be done properly by performing an actual
measurement.
Acesst 1.0 6251194