4
Support
measurement
376
Trend Monitor
FZ3 Processing Items List Manual
Key Points for Test Measurement and Adjustment (Trend Monitor)
The following content can be confirmed in the "Detail result" area using text.
Displayed
items
Description
Judge
Judgement result
Measurement Latest measured value
Max
Max. measurement value during recording period
Min
Min. measurement value during recording period
Standard
deviation
Standard deviation for measurement values during recording period
Plus 3σ
Average of measurement values during period re standard deviation of the measurement
values x 3
Plus σ
Average of measurement values during period re standard deviation of the measurement
values
Average
Average value for measurement values during recording period
Minus σ
Average of measurement values during period recorded - standard deviation of the measurement
values
Minus 3σ
Average of measurement values during period recorded - standard deviation of the measurement
values x 3
Measurement
count
Measure count since the beginning of measurement
OK count
Number of measurements since starting to make measurements - NG count in number of
measurements
NG count
Number of NG occurrences within the measurement count
Warning
count
Warning count within the measurement count
Yield
OK count in number of measurements / Number of measurements since starting to make
measurements
Measurement Results for Which Output Is Possible (Trend Monitor)
The following values can be output using processing items related to results output.It is also possible to
reference measurement values from expressions and other processing units.
Measurement
items
Character
string
Description
Judgement
JG
Judgement result
Measurement DT
Latest measured value
Warning
WN
Existence of warning occurrence
Maximum
MX
Max. measurement value during recording period
Minimum
MN
Min. measurement value during recording period
Deviation
DV
Standard deviation for measurement values during recording period
Plus 3σ
AP3
Average of measurement values during period re standard deviation of the
measurement values x 3
Plus σ
AP1
Average of measurement values during period re standard deviation of the
measurement values
Average
AV
Average value for measurement values during recording period
Minus σ
AM1
Average of measurement values during period recorded - standard deviation of the
measurement values
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...