2
Measurement
FZ3 Processing Items List Manual
L
195
Setting item
Set value
[Factory default]
Description
Binary level
Upper limit
0 to 255
[255]
Specify the level for converting 256-tone
grayscale images to binary images.Adjust the
binary level so that the measurement object is
converted to white pixels.You can also set the
binary level so that only intermediate density is
measured.
Lower limit
0 to 255
[128]
Auto setting
—
Optimum binary levels are calculated
automatically and set.
Reverse
●
Checked
●
[Unchecked]
This item reverses black and white colors.
When Dyn threshold is selected
Setting item
Set value
[Factory default]
Description
Offset value
0 to 127
[5]
This sets the offset for the difference between the input image
and that input image after it has been subject to brightness
averaging.The higher this value, the easier it is to extract
locations (such as edges) with large density difference.
Reverse
●
Checked
●
[Unchecked]
This item reverses black and white colors.
Perform the [Detail setting] if required.