![background image](http://html.mh-extra.com/html/omron/xpectia-fz3/xpectia-fz3_user-manual_1633321402.webp)
5
Branch
400
Conditional Branch
FZ3 Processing Items List Manual
A<B
If the value from expression A is lower than the value from expression B, moves to
the unit in which "Destination unit" is YES.
If A is equal to or greater than B, moves to the NO unit.
A>=B
If the value from expression A is equal to that of expression B, or if the value of A is
higher than that of B, moves to the unit in which "Destination unit" is "YES". If B is
higher, moves to the unit with "NO".
A>B
If the value from expression A is higher than the value from expression B, moves to
the unit in which "Destination unit" is YES.
If A is equal to or less than B, moves to the NO unit.
3.
Set the branch destination.
Important
●
In order to avoid measurement processing looping, for the branch destination, set a processing unit
number that is after the [Conditional Branch].
●
Make sure to set "End" at the last branch destination to indicate the end of the branch.
Reference:
End (p.403)
Note
●
The judgement result for a processing unit is finalized when that processing unit is processed.
●
The overall judgement is finalized when all processing unit measurement is complete.
Conditional Branch Settings Examples
The overall judgement result for processing up to the unit number in which the expression is set is
acquired and subsequent measurement is branched according the result.
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...