1.
Tap [Mask register].
2.
Draw the mask figure using the drawing tools.
3.
Tap [OR/NOT].
The mask figure is displayed in red.
4.
In the figure setting area, tap [OK].
Adjusting the Edge Level
In an ECM search, processing is executed on the edge extraction image. Change this item as necessary
when the edge is not extracted or is extracted along with noise.
Important
●
In model registration, extract as much of the edge as possible, then delete noise etc. in the mask registration to
register the entire edge of the model. On the other hand, when measuring, even if the edge has skips, an image
with the noise suppressed makes it possible to search the model stably. To set separate edge extraction
conditions for model registration and for measuring, after registering the model, change the edge extraction
conditions.
1.
In the item tab area, tap [Edge extraction].
2.
Set the items in the "Edge extraction setting" area.
Setting item
Setting
value
[Factory
default]
Description
Mask size
●
3x3
●
[5 x 5]
●
7x7
●
9x9
Select the range of pixels which are used to extract the edge. With a
larger mask size, search is less affected by variation in pixels.
Edge Level
0 to 255
[100]
Adjust the edge extraction level when the edge is hard to see due to
low contrast with the background or when unnecessary background
noise should be removed.
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...