FTMx_COMBINE field descriptions (continued)
Field
Description
Enables the capture of the FTM counter value according to the channel (n) input event and the
configuration of the dual edge capture bits.
This field applies only when DECAPEN = 1.
DECAP bit is cleared automatically by hardware if dual edge capture – one-shot mode is selected and
when the capture of channel (n+1) event is made.
0
The dual edge captures are inactive.
1
The dual edge captures are active.
26
DECAPEN3
Dual Edge Capture Mode Enable For n = 6
Enables the Dual Edge Capture mode in the channels (n) and (n+1). See
This field is write protected. It can be written only when MODE[WPDIS] = 1.
25
COMP3
Complement Of Channel (n) for n = 6
In Complementary mode the channel (n+1) output is the inverse of the channel (n) output.
This field is write protected. It can be written only when MODE[WPDIS] = 1.
0
The channel (n+1) output is the same as the channel (n) output.
1
The channel (n+1) output is the complement of the channel (n) output.
24
COMBINE3
Combine Channels For n = 6
Used on the selection of the combine mode for channels (n) and (n+1). See
This field is write protected. It can be written only when MODE[WPDIS] = 1.
23
Reserved
This field is reserved.
This read-only field is reserved and always has the value 0.
22
FAULTEN2
Fault Control Enable For n = 4
Enables the fault control in channels (n) and (n+1).
This field is write protected. It can be written only when MODE[WPDIS] = 1.
0
The fault control in this pair of channels is disabled.
1
The fault control in this pair of channels is enabled.
21
SYNCEN2
Synchronization Enable For n = 4
Enables PWM synchronization of registers C(n)V and C(n+1)V.
0
The PWM synchronization in this pair of channels is disabled.
1
The PWM synchronization in this pair of channels is enabled.
20
DTEN2
Deadtime Enable For n = 4
Enables the deadtime insertion in the channels (n) and (n+1).
This field is write protected. It can be written only when MODE[WPDIS] = 1.
0
The deadtime insertion in this pair of channels is disabled.
1
The deadtime insertion in this pair of channels is enabled.
19
DECAP2
Dual Edge Capture Mode Captures For n = 4
Enables the capture of the FTM counter value according to the channel (n) input event and the
configuration of the dual edge capture bits.
This field applies only when DECAPEN = 1.
Table continues on the next page...
Chapter 41 FlexTimer Module (FTM)
Kinetis KE1xF Sub-Family Reference Manual, Rev. 4, 06/2019
NXP Semiconductors
993
Summary of Contents for KE1xF Series
Page 2: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 2 NXP Semiconductors...
Page 138: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 138 NXP Semiconductors...
Page 360: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 360 NXP Semiconductors...
Page 490: ...Interrupts Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 490 NXP Semiconductors...
Page 562: ...Boot Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 562 NXP Semiconductors...
Page 706: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 706 NXP Semiconductors...
Page 736: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 736 NXP Semiconductors...
Page 866: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 866 NXP Semiconductors...
Page 1164: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1164 NXP Semiconductors...
Page 1178: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1178 NXP Semiconductors...
Page 1380: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1380 NXP Semiconductors...
Page 1472: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1472 NXP Semiconductors...
Page 1482: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1482 NXP Semiconductors...