41.5.17 Fault control
The fault control is enabled if (FAULTM[1:0] ≠ 0:0).
FTM can have up to four fault inputs. FAULTnEN bit (where n = 0, 1, 2, 3) enables the
fault input n and FFLTRnEN bit enables the fault input n filter. FFVAL[3:0] bits select
the value of the enabled filter in each enabled fault input.
First, each fault input signal is synchronized by the FTM input clock; see the
synchronizer block in the following figure. Following synchronization, the fault input n
signal enters the filter block. The filter clock is prescaled and controlled by FLTPS[3:0]
bits. When there is a state change in the fault input n signal, the 5-bit counter is reset and
starts counting up. As long as the new state is stable on the fault input n, the counter
continues to increment. If the 5-bit counter overflows, that is, the counter exceeds the
value of the FFVAL[3:0] bits, the new fault input n value is validated. It is then
transmitted as a pulse edge to the edge detector.
If the opposite edge appears on the fault input n signal before validation (counter
overflow), the counter is reset. At the next input transition, the counter starts counting
again. Any pulse that is shorter than the minimum value selected by FFVAL[3:0] bits (×
filter clock) is regarded as a glitch and is not passed on to the edge detector.
The fault input n filter is disabled when the FFVAL[3:0] bits are zero or when
FAULTnEN = 0. In this case, the fault input n signal is delayed 2 rising edges of the
FTM input clock and the FAULTFn bit is set on 3th rising edge of the FTM input clock
after a rising edge occurs on the fault input n.
If FFVAL[3:0] ≠ 0000 and FAULTnEN = 1, then the delay is (2 FTM input (2 +
FFVAL) filter clk), that is, the FAULTFn bit is set (2 FTM input 2 filter clocks
+ FFVAL[3:0]) clock edges after a rising edge occurs on the fault input n.
fault input n*
FTM input
clock
* where n = 3, 2, 1, 0
synchronizer
fault input n* value
FAULTFn*
0000)
and (FFLTRnEN*)
0
1
rising edge
detector
fault input
polarity
control
Fault filter
(5-bit counter)
CLK
D
Q
FLTnPOL
(FFVAL[3:0]
filter
prescaler
CLK
D
Q
filter clock
Figure 41-71. Fault input n control block diagram
If the fault control and fault input n are enabled and a rising edge at the fault input n
signal is detected, a fault condition has occurred and the FAULTFn bit is set. The
FAULTF bit is the logic OR of FAULTFn[3:0] bits. See the following figure.
Chapter 41 FlexTimer Module (FTM)
Kinetis KE1xF Sub-Family Reference Manual, Rev. 4, 06/2019
NXP Semiconductors
1073
Summary of Contents for KE1xF Series
Page 2: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 2 NXP Semiconductors...
Page 138: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 138 NXP Semiconductors...
Page 360: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 360 NXP Semiconductors...
Page 490: ...Interrupts Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 490 NXP Semiconductors...
Page 562: ...Boot Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 562 NXP Semiconductors...
Page 706: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 706 NXP Semiconductors...
Page 736: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 736 NXP Semiconductors...
Page 866: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 866 NXP Semiconductors...
Page 1164: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1164 NXP Semiconductors...
Page 1178: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1178 NXP Semiconductors...
Page 1380: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1380 NXP Semiconductors...
Page 1472: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1472 NXP Semiconductors...
Page 1482: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1482 NXP Semiconductors...