17.5.11.9 Read 1s All Blocks command
The Read 1s All Blocks command checks if the program flash blocks, data flash blocks,
EEPROM backup records, and data flash IFR have been erased to the specified read
margin level, if applicable, and releases security if the readout passes, i.e. all data reads as
'1'.
Table 17-27. Read 1s All Blocks Command FCCOB Requirements
FCCOB Number
FCCOB Contents [7:0]
0
0x40 (RD1ALL)
1
Read-1 Margin Choice
After clearing CCIF to launch the Read 1s All Blocks command, the FTFE :
• sets the read margin for 1s according to
,
• checks the contents of the program flash, data flash, EEPROM backup records, and
data flash IFR are in the erased state.
If the FTFE confirms that these memory resources are erased, access control is disabled
and security is released by setting the FSEC[SEC] field to the unsecure state. The
security byte in the flash configuration field (see
Flash configuration field description
)
remains unaffected by the Read 1s All Blocks command. If the read fails, i.e. all flash
memory resources are not in the fully erased state, the FSTAT[MGSTAT0] bit is set.
The EEERDY and RAMRDY bits are clear during the Read 1s All Blocks operation and
are restored at the end of the Read 1s All Blocks operation.
The CCIF flag sets after the Read 1s All Blocks operation has completed.
Table 17-28. Margin Level Choices for Read 1s All Blocks
Read Margin Choice
Margin Level Description
0x00
Use the 'normal' read level for 1s
0x01
Apply the 'User' margin to the normal read-1 level
0x02
Apply the 'Factory' margin to the normal read-1 level
Table 17-29. Read 1s All Blocks Command Error Handling
Error Condition
Error Bit
Command not available in current mode/security
FSTAT[ACCERR]
An invalid margin choice is specified
FSTAT[ACCERR]
Read-1s fails
FSTAT[MGSTAT0]
Functional Description
Kinetis KE1xF Sub-Family Reference Manual, Rev. 4, 06/2019
420
NXP Semiconductors
Summary of Contents for KE1xF Series
Page 2: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 2 NXP Semiconductors...
Page 138: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 138 NXP Semiconductors...
Page 360: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 360 NXP Semiconductors...
Page 490: ...Interrupts Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 490 NXP Semiconductors...
Page 562: ...Boot Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 562 NXP Semiconductors...
Page 706: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 706 NXP Semiconductors...
Page 736: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 736 NXP Semiconductors...
Page 866: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 866 NXP Semiconductors...
Page 1164: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1164 NXP Semiconductors...
Page 1178: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1178 NXP Semiconductors...
Page 1380: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1380 NXP Semiconductors...
Page 1472: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1472 NXP Semiconductors...
Page 1482: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1482 NXP Semiconductors...