CHAPTER 21 LCD CONTROLLER
User’s Manual U14272EJ3V0UM
412
Table 21-3. LCD Controller Parameters
Symbol
Definition
Tg
gclk period
This parameter is not one of the timing parameters, but all timing parameters is
calculated based on this. gclk is controlled by the Pre-scal field.
Tg = 1 / (frequency of gclk)
T1
Shift clock high level width
Color: T1 = Tg x HpckH
4-bit bus monochrome: T1 = Tg x (HpckH + HpckL)
T2
Shift clock cycle
Color: T2 = Tg x (HpckH + HpckL)
4-bit bus monochrome: T2 = Tg x (HpckH + HpckL) x 2
T3
Panel data setup time
Color : T3 = Tg x HpckH
4-bit bus monochrome: T3 = Tg x (HpckH + HpckL)
T4
Panel data hold time
Color: T4 = Tg x HpckL
4-bit bus monochrome: T4 = Tg x (HpckH + HpckL)
T5
Row cycle time
T5 = Tg x (HpckH + HpckL) x Htot
T6
Load clock start time
T6 = Tg x (HpckH + HpckL) x LCS
T7
Load clock end time
T7 = Tg x (HpckH + HpckL) x LCE
T8
FLM horizontal start time
T8 = Tg x (HpckH + HpckL) x FLMHS
T9
FLM horizontal end time
T9 = Tg x (HpckH + HpckL) x FLMHE
T10
Panel frame period
T10 = Tg x (HpckH + HpckL) x Htot x Vtot