CHAPTER 14 TOUCH PANEL INTERFACE UNIT (PIU)
User’s Manual U14272EJ3V0UM
294
14.3.10 PIUABnREG (0x0B00 02B0 to 0x0B00 02B6)
Remark
n = 0 to 3
PIUAB0REG (0x0B00 02B0)
PIUAB1REG (0x0B00 02B2)
PIUAB2REG (0x0B00 02B4)
PIUAB3REG (0x0B00 02B6)
Bit
15
14
13
12
11
10
9
8
Name
VALID
Reserved
Reserved
Reserved
Reserved
Reserved
PADDATA9
PADDATA8
R/W
R/W
R
R
R
R
R
R/W
R/W
RTCRST
0
0
0
0
0
0
0
0
Other resets
0
0
0
0
0
0
0
0
Bit
7
6
5
4
3
2
1
0
Name
PADDATA7
PADDATA6
PADDATA5
PADDATA4
PADDATA3
PADDATA2
PADDATA1
PADDATA0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RTCRST
0
0
0
0
0
0
0
0
Other resets
0
0
0
0
0
0
0
0
Bit
Name
Function
15
VALID
Indicates validity of data in buffer
1 : Valid
0 : Invalid
14 to 10
Reserved
0 is returned when read
9 to 0
PADDATA(9:0)
A/D converter’s sampling data
These registers are used to store sampling data of the general-purpose A/D port and audio input port or command
scan data. There are four data buffers and the addresses (register address) where the data is stored are fixed.
The VALID bit, which indicates whether the data is valid, is automatically rendered invalid when the page buffer
interrupt source (the PADADPINTR bit in the PIUINTREG register) is cleared.
Table 14-6 shows correspondences between the sampled data and the register in which the sampled data is
stored.
Table 14-6. A/D Ports and Data Buffers
Register
During ADPScan
During CMDScan
TPPSCAN = 0
TPPSCAN = 1
PIUAB0REG
PIUAB1REG
PIUAB2REG
PIUAB3REG
ADIN0
ADIN1
ADIN2
AUDIOIN
TPX0
TPX1
TPY0
TPY1
CMDScan data
−
−
−