CHAPTER 14 TOUCH PANEL INTERFACE UNIT (PIU)
User’s Manual U14272EJ3V0UM
284
14.3.2 PIUINTREG (0x0B00 0124)
Bit
15
14
13
12
11
10
9
8
Name
OVP
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
R/W
R/W
R
R
R
R
R
R
R
RTCRST
0
0
0
0
0
0
0
0
Other resets
0
0
0
0
0
0
0
0
Bit
7
6
5
4
3
2
1
0
Name
Reserved
PADCMD
INTR
PADADP
INTR
PADPAGE1
INTR
PADPAGE0
INTR
PADDLOST
INTR
Reserved
PENCHG
INTR
R/W
R
R/W
R/W
R/W
R/W
R/W
R
R/W
RTCRST
0
0
0
0
0
0
0
0
Other resets
0
0
0
0
0
0
0
0
Bit
Name
Function
15
OVP
Valid page ID bit (older valid page)
1 : Page 1 retains an older valid data
0 : Page 0 retains an older valid data
14 to 7
Reserved
0 is returned when read
6
PADCMDINTR
PIU command scan interrupt request. This interrupt request occurs when a valid data
is obtained during a command scan. Cleared to 0 when 1 is written.
1 : Occurred
0 : Not occurred
5
PADADPINTR
PIU A/D port scan interrupt request. This interrupt request occurs when a set of valid
data is obtained during an A/D port scan. Cleared to 0 when 1 is written.
1 : Occurred
0 : Not occurred
4
PADPAGE1INTR
PIU data buffer page 1 interrupt request. This interrupt request occurs when a set of
valid data is stored in the page 1 of the data buffer. Cleared to 0 when 1 is written.
1 : Occurred
0 : Not occurred
3
PADPAGE0INTR
PIU data buffer page 0 interrupt request. This interrupt request occurs when a set of
valid data is stored in the page 0 of the data buffer. Cleared to 0 when 1 is written.
1 : Occurred
0 : Not occurred
2
PADDLOSTINTR
Data lost interrupt request. This interrupt request occurs when a set of data cannot be
obtained during a specified time period. Cleared to 0 when 1 is written.
1 : Occurred
0 : Not occurred
1
Reserved
0 is returned when read
0
PENCHGINTR
Touch panel contact status change interrupt request. Cleared to 0 when 1 is written.
1 : Occurred
0 : Not occurred