CHAPTER 11 REALTIME CLOCK UNIT (RTC)
User’s Manual U14272EJ3V0UM
222
(2) RTCL1HREG (0x0B00 00D2)
Bit
15
14
13
12
11
10
9
8
Name
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
R/W
R
R
R
R
R
R
R
R
RTCRST
0
0
0
0
0
0
0
0
Other resets
Note
Note
Note
Note
Note
Note
Note
Note
Bit
7
6
5
4
3
2
1
0
Name
RTCL1P23
RTCL1P22
RTCL1P21
RTCL1P20
RTCL1P19
RTCL1P18
RTCL1P17
RTCL1P16
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RTCRST
0
0
0
0
0
0
0
0
Other resets
Note
Note
Note
Note
Note
Note
Note
Note
Bit
Name
Function
15 to 8
Reserved
0 is returned when read
7 to 0
RTCL1P(23:16)
Bits 23 to 16 for RTCLong1 timer count cycle
Note Holds the value before reset.
Use these registers to set the RTCLong1 timer count cycle. The RTCLong1 timer begins its countdown at the
value written to these registers.
A write operation is valid once values have been written to both registers (RTCL1LREG and RTCL1HREG).
When setting these registers again, wait until at least 100
µ
s (three cycles of 32.768 kHz clock) have elapsed after
the first setting.
Cautions 1.
The RTCLong1 timer is stopped when all zeros are written.
2.
Any combined setting of “RTCL1HREG = 0x0000” and “RTCL1LREG = 0x0001, 0x0002,
0x0003, or 0x0004” is prohibited.