CHAPTER 11 REALTIME CLOCK UNIT (RTC)
User’s Manual U14272EJ3V0UM
226
(2) RTCL2HREG (0x0B00 00DA)
Bit
15
14
13
12
11
10
9
8
Name
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
R/W
R
R
R
R
R
R
R
R
RTCRST
0
0
0
0
0
0
0
0
Other resets
Note
Note
Note
Note
Note
Note
Note
Note
Bit
7
6
5
4
3
2
1
0
Name
RTCL2P23
RTCL2P22
RTCL2P21
RTCL2P20
RTCL2P19
RTCL2P18
RTCL2P17
RTCL2P16
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RTCRST
0
0
0
0
0
0
0
0
Other resets
Note
Note
Note
Note
Note
Note
Note
Note
Bit
Name
Function
15 to 8
Reserved
0 is returned when read
7 to 0
RTCL2P(23:16)
Bits 23 to 16 for RTCLong2 timer count cycle
Note Holds the value before reset.
Use these registers to set the RTCLong2 timer count cycle. The RTCLong2 timer begins its countdown at the
value written to these registers.
A write operation is valid once values have been written to both registers (RTCL2LREG and RTCL2HREG).
When setting these registers again, wait until at least 100
µ
s (three cycles of 32.768 kHz clock) have elapsed after
the first setting.
Cautions 1.
The RTCLong2 timer is stopped when all zeros are written.
2.
Any combined setting of “RTCL2HREG = 0x0000” and “RTCL2LREG = 0x0001, 0x0002,
0x0003, or 0x0004” is prohibited.