CHAPTER 14 TOUCH PANEL INTERFACE UNIT (PIU)
User’s Manual U14272EJ3V0UM
286
Figure 14-5. Interval Times and States
State
Operation
DataScan
Interval
ADPScan
Interval
DataScan
S A S A S A S A
Interval time
S T
A A A A
T
S A S A S A S A
Remark
S: Voltage stabilization wait time (STABLE(5:0) in PIUSTBLREG)
A: A/D converter conversion time (about 10
µ
s)
T: Touch/release detection
14.3.4 PIUSTBLREG (0x0B00 0128)
Bit
15
14
13
12
11
10
9
8
Name
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
R/W
R
R
R
R
R
R
R
R
RTCRST
0
0
0
0
0
0
0
0
Other resets
0
0
0
0
0
0
0
0
Bit
7
6
5
4
3
2
1
0
Name
Reserved
Reserved
STABLE5
STABLE4
STABLE3
STABLE2
STABLE1
STABLE0
R/W
R
R
R/W
R/W
R/W
R/W
R/W
R/W
RTCRST
0
0
0
0
0
1
1
1
Other resets
0
0
0
0
0
1
1
1
Bit
Name
Function
15 to 6
Reserved
0 is returned when read
5 to 0
STABLE(5:0)
Touch panel voltage stabilization wait time (DataScan, CMDScan state)
A/D scan timeout time (ADPScan state)
Touch detection start wait time (Disable, WaitPenTouch, Interval state)
Wait time = STABLE(5:0)
×
30
µ
s
The voltage stabilization wait time for the power applied to the touch panel can be set via the STABLE(5:0) bits in
30
µ
s units between 0
µ
s and 1,890
µ
s.