![background image](http://html.mh-extra.com/html/nec/express5800-120mf/express5800-120mf_user-manual_251193224.webp)
6-10 Troubleshooting
POST Error Codes and Messages (continued)
Error Code and Message
Description
Action
0B99
BMC Fatal hardware
error
0B9A
BMC not responding
0B9B
Private I2C bus not
responding
0B9C
BMC internal exception
0B9D
BMC A/D timeout error
0B9E
SDR repository corrupt
0B9F SEL
corrupt
0BB0
SMBIOS - SROM data
read error
Read error of SROM data.
0BB1
SMBIOS - SROM data
checksum bad
Checksum for the SROM data
is incorrect.
0BC0
POST detected startup
failure of 1
st
Processor
CPU #1 failed to startup.
0BC1
POST detected startup
failure of 2
nd
Processor
CPU #2 failed to startup.
Contact your service
representative to replace the
failed CPU.
0BD0
1st SMBus device
address not
acknowledged
No response was made to the
access to the 1st SMBus.
0BD1
1st SMBus device Error
detected
An error was detected in the
access to the 1st SMBus.
0BD2
1st SMBus timeout
A timeout error occurred in the
access to the 1st SMBus.
0BD3
2nd SMBus device
address not
acknowledged
No response was made to the
access to the 2nd SMBus.
0BD4
2nd SMBus device Error
detected
An error was detected in the
access to the 2nd SMBus.
0BD5
2nd SMBus timeout
A timeout error occurred in the
access to the 2nd SMBus.
0BD6
3rd SMBus device
address not
acknowledged
No response was made to the
access to the 3rd SMBus.
Contact your service
representative to replace the
board indicated in the system
event log.
Summary of Contents for EXPRESS5800/120MF
Page 1: ... EXPRESS5800 120Mf U s e r s G u i d e ...
Page 2: ......
Page 4: ......
Page 12: ...x ...
Page 24: ...1 6 System Overview Rear View 11 9 10 12 13 14 15 16 2 17 15 18 17 16 1 8 7 6 1 2 3 4 5 2 5 1 ...
Page 58: ...1 40 System Overview This page is intentionally left blank ...
Page 59: ...Chapter 2 Setting Up Your Server This chapter describes how to set up your server ...
Page 202: ...4 62 Installing the Operating System and Utilities This page is intentionally left blank ...
Page 214: ...5 12 Maintenance This page is intentionally left blank ...
Page 229: ...Troubleshooting 6 15 Memory modules DIMM Group 3 DIMM Group 2 DIMM Group 1 ...
Page 304: ...7 50 Upgrading your Server This page is intentionally left blank ...
Page 305: ...Chapter 8 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 318: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...
Page 326: ...C 8 Installing Windows 2000 This page is intentionally left blank ...
Page 340: ...10 Glossary This page is intentionally left blank ...
Page 345: ...xx ...
Page 346: ... ...