Configuring Your System 3-25
Option Parameter Description
Your
Setting
Service Partition
Type
–
Indicates the type of the service
partition.
Assert NMI on
PERR
Disabled
[Enabled]
Indicates whether PCI PERR is
supported or not.
Assert NMI on
SERR
Disabled
[Enabled]
Indicates whether PCI SERR is
supported or not.
FRB-2 Policy
Disable FRB2 Timer
[Disable BSP]
Do not Disable BSP
Retry 3 Times
Set this item to "Disable BSP."
Boot Monitoring
[Disabled]
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Disables or enables the boot
monitoring feature. Set to disabled
when installing OS. Once OS is
installed, re-enable.
To use this function, install NEC
ESMPRO Agent. Do not use this
function if the system is booted
from the OS without installation of
NEC ESMPRO Agent or CD-ROM.
Set this item to "Disabled" if
ARCServe uses the Disaster
Recovery Option.
Boot Monitoring
Policy
[Retry 3 times]
Retry Service Boot
Always Reset
Indicates the policy when the timer
expired on booting.
Thermal Sensor
Disabled
[Enabled]
Enables or disables temperature
sensor monitoring feature.
BMC IRQ
Disabled
5
10
[11]
Sets the BMC IRQ.
Post Error Pause
Disabled
[Enabled]
Specifies whether the system waits
for user intervention on critical
POST errors or not.
AC-LINK Stay
Off
[Last State]
Power On
Sets the AC-LINK feature.
Determines the mode of operation
if a power loss occurs. (See the
table below.)
[ ]: Factory-set
The table below lists how selections for "AC-LINK" determine the power status of the server when
the power supply to the server restarts.
Parameter
State before powered off
Stay Off
Last State
Power On
In service
Off
On On
Out of service (DC power: Off)
Off
Off On
Forced shutdown *
Off
Off On
* Pressing the POWER switch for at least four seconds shuts down the power to the server.
Summary of Contents for EXPRESS5800/120MF
Page 1: ... EXPRESS5800 120Mf U s e r s G u i d e ...
Page 2: ......
Page 4: ......
Page 12: ...x ...
Page 24: ...1 6 System Overview Rear View 11 9 10 12 13 14 15 16 2 17 15 18 17 16 1 8 7 6 1 2 3 4 5 2 5 1 ...
Page 58: ...1 40 System Overview This page is intentionally left blank ...
Page 59: ...Chapter 2 Setting Up Your Server This chapter describes how to set up your server ...
Page 202: ...4 62 Installing the Operating System and Utilities This page is intentionally left blank ...
Page 214: ...5 12 Maintenance This page is intentionally left blank ...
Page 229: ...Troubleshooting 6 15 Memory modules DIMM Group 3 DIMM Group 2 DIMM Group 1 ...
Page 304: ...7 50 Upgrading your Server This page is intentionally left blank ...
Page 305: ...Chapter 8 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 318: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...
Page 326: ...C 8 Installing Windows 2000 This page is intentionally left blank ...
Page 340: ...10 Glossary This page is intentionally left blank ...
Page 345: ...xx ...
Page 346: ... ...