Installing the Operating System and Utilities 4-13
5.
Click [Link Config] and specify the Speed value & Duplex value according to the value
specified for HUB.
6.
Click [OK] on the [Intel(R)PROSetII] dialog box.
Also, add or delete any protocols and services as required. Perform these actions from the property
dialogue box of the local area connection under [Network and Dial-up Connection].
NOTE:
We recommend you add [Network Monitor] at [Add/Remove
Programs]. [Network Monitor] can monitor frames (or packets) that this
computer sends or receives. It is a valuable tool when analyzing network
trouble. For information on how to install the [Network Monitor], see the
section "Setup for Problem Resolution" later in this document.
Graphics Accelerator Driver
Update the installed standard Graphics Accelerator Driver.
If you want to utilize an optional Graphics Accelerator Driver board, follow the document provided
with the board to install the driver.
1.
Insert the EXPRESSBUILDER CD-ROM into the CD-ROM drive.
2.
Click Start menu, point to [Programs], [Accessories] and click [Windows Explorer].
3.
Run "Setup.exe" in the following directory.
<CD-ROM Drive Letter>:\WINNT\VIDEO\W2K\setup.exe.
4.
Follow the messages to continue the installation.
If the dialog message "Digital Signature could not been found." appears, select [Yes] to
continue.
5.
Remove the EXPRESSBUILDER CD-ROM from the CD-ROM drive, follow the
direction on the screen and restart the system.
Summary of Contents for EXPRESS5800/120MF
Page 1: ... EXPRESS5800 120Mf U s e r s G u i d e ...
Page 2: ......
Page 4: ......
Page 12: ...x ...
Page 24: ...1 6 System Overview Rear View 11 9 10 12 13 14 15 16 2 17 15 18 17 16 1 8 7 6 1 2 3 4 5 2 5 1 ...
Page 58: ...1 40 System Overview This page is intentionally left blank ...
Page 59: ...Chapter 2 Setting Up Your Server This chapter describes how to set up your server ...
Page 202: ...4 62 Installing the Operating System and Utilities This page is intentionally left blank ...
Page 214: ...5 12 Maintenance This page is intentionally left blank ...
Page 229: ...Troubleshooting 6 15 Memory modules DIMM Group 3 DIMM Group 2 DIMM Group 1 ...
Page 304: ...7 50 Upgrading your Server This page is intentionally left blank ...
Page 305: ...Chapter 8 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 318: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...
Page 326: ...C 8 Installing Windows 2000 This page is intentionally left blank ...
Page 340: ...10 Glossary This page is intentionally left blank ...
Page 345: ...xx ...
Page 346: ... ...