Troubleshooting 6-7
POST Error Codes and Messages (continued)
Error Code and Message
Description
Action
0B01
Rebooted during OS
boot
0B02
Rebooted during OS
runtime
0B1B
PCI system error on
Bus/Device/Function
0B1C
PCI parity error on
Bus/Device/Function
OB22 Processors
are
installed out of order
0B28 Unsupported
Processor detected
on Processor 1
Unsupported CPU (old version) is
mounted in CPU slot.
Contact your service
representative to replace the
failed CPU (number).
0B29 Unsupported
Processor detected
on Processor 2
Unsupported CPU (old version) is
mounted in CPU slot.
Contact your service
representative to replace the
failed CPU (number).
0B30
|
0B34
Fan Alarm 1 – 5
occurred
Fan error.
Contact your service
representative to replace the
faulty fan indicated in the
system event log.
0B50
Processor #1 with
error taken off line
Because an error was detected in
CPU #1, it was degraded.
0B51
Processor #2 with
error taken off line
Because an error was detected in
CPU #2, it was degraded.
The displayed CPU is
degraded. Contact your service
representative to replace the
failed CPU.
0B5F
Forced to use
Processor with error
CPU error is detected.
The system is started forcibly
because errors are detected on
all CPUs. Contact your service
representative to replace the
CPU.
0B60
DIMM group #1 has
been disabled
A memory error was detected in
memory DIMM group #1. Memory
DIMM group #1 is degraded.
0B61
DIMM group #2 has
been disabled
A memory error was detected in
memory DIMM group #2. Memory
DIMM group #2 is degraded.
0B62
DIMM group #3 has
been disabled
A memory error was detected in
memory DIMM group #3. Memory
DIMM group #3 is degraded.
Contact your service
representative to replace the
DIMM board.
Summary of Contents for EXPRESS5800/120MF
Page 1: ... EXPRESS5800 120Mf U s e r s G u i d e ...
Page 2: ......
Page 4: ......
Page 12: ...x ...
Page 24: ...1 6 System Overview Rear View 11 9 10 12 13 14 15 16 2 17 15 18 17 16 1 8 7 6 1 2 3 4 5 2 5 1 ...
Page 58: ...1 40 System Overview This page is intentionally left blank ...
Page 59: ...Chapter 2 Setting Up Your Server This chapter describes how to set up your server ...
Page 202: ...4 62 Installing the Operating System and Utilities This page is intentionally left blank ...
Page 214: ...5 12 Maintenance This page is intentionally left blank ...
Page 229: ...Troubleshooting 6 15 Memory modules DIMM Group 3 DIMM Group 2 DIMM Group 1 ...
Page 304: ...7 50 Upgrading your Server This page is intentionally left blank ...
Page 305: ...Chapter 8 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 318: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...
Page 326: ...C 8 Installing Windows 2000 This page is intentionally left blank ...
Page 340: ...10 Glossary This page is intentionally left blank ...
Page 345: ...xx ...
Page 346: ... ...