App - 3 App - 3
MELSEC-Q
APPENDIX
(3) Operation timing and processing time of position control
[X18 to X1F]
t6
Md. 7
Pulse output to outside
(PULSE)
BUSY signal [X8 to XF]
Md. 4
Positioning start signal
[Y8 toYF]
[X10 to X17]
t4
t1
t2
t3
t5
Axis operation status
Standby
position control
Standby
Start complete signal
Machine OPR control
operation
Positioning complete signal
OPR complete flag
[ Status : b1]
t1
t2
t3
t4
t5
t6
0.1 to 0.5ms
0.2ms
0 to 2ms
0 to 2ms
0 to 2ms
As set in
parameter
: t1 at simultaneous start of multiple axes
Number of started axes
t1
1 axis
0.1ms
4 axes
0.2ms
8 axes
0.4ms
A delay may occur depending on the operating conditions and starting conditions
(control method, bias speed, ACC/DEC time, etc.) of the other axes.