4 - 20 4 - 20
MELSEC-Q
4 DATA USED FOR POSITIONING CONTROL
4.4 List of JOG data
Setting value buffer memory address
Item
Setting value, setting
range
Default value
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7 Axis 8
JOG. 1 JOG speed
1 to 200000 (pulse/s)
0
40
41
140
141
240
241
340
341
440
441
540
541
640
641
740
741
JOG. 2 JOG ACC time
0 to 32767 (ms)
1000
42
142
242
342
442
542
642
742
JOG. 3 JOG DEC time
0 to 32767 (ms)
1000
43
143
243
343
443
543
643
743
0: Forward run JOG
JOG. 4 JOG direction flag
1: Reverse run JOG
0
44
144
244
344
444
544
644
744
JOG. 1
JOG speed
Set the speed for JOG operation. (This value is used for both forward run JOG
and reverse run JOG.)
Set the JOG speed in the following range.
( Pr. 5 Speed limit value)
≥
( JOG. 1 JOG speed)
≥
( Pr. 6 Bias speed at start)
If the "JOG speed" is more than the "speed limit value", it is limited to " Pr. 5
Speed limit value".
If the "JOG speed" is less than " Pr. 6 Bias speed at start", it is limited to "Pr. 6
Bias speed at start".
JOG. 2
JOG ACC time
Set the time taken to reach " JOG. 1 JOG speed" from " Pr. 6 Bias speed at
start" at a JOG operation start (JOG start signal ON). (This value is used for both
forward run JOG and reverse run JOG.)
JOG. 3
JOG DEC time
Set the time taken to make a stop after reaching " Pr. 6 Bias speed at start" from
" JOG. 1 JOG speed" at a JOG operation stop (JOG start signal OFF, error
occurrence). (This value is used for both forward run JOG and reverse run JOG.)
JOG. 4
JOG direction flag
Set the forward/reverse direction for JOG operation.
0: Forward run JOG
1: Reverse run JOG