3 - 3 3 - 3
MELSEC-Q
3 SPECIFICATIONS AND FUNCTIONS
With the "positioning control", whether or not to continuously execute the positioning
data can be set with the "operation pattern". Outlines of the "operation patterns" are
given below.
Da.1
Operation pattern
Description
Reference
Positioning termination
When "Positioning termination" is set for the operation pattern
of the started positioning data, only the designated positioning
data will be executed, and then the positioning control will end.
Continuous positioning control
When "continuous positioning control" is set for the operation
pattern of the started positioning data, after the designated
positioning data is executed, the program will stop once, and
then the next following positioning data will be executed.
Continuous path control
When "continuous path control" is set for the operation pattern
of the started positioning data, the designated positioning data
will be executed, and then without decelerating, the next
following positioning data will be executed.
9.1.2
Summary of Contents for GX Configurator-PT
Page 13: ...MEMO SECTION 1...
Page 127: ...7 20 7 20 MELSEC Q 7 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO...
Page 129: ...MEMO SECTION 2...
Page 221: ...Index 5 Index 5 MEMO...