5 - 20 5 - 20
MELSEC-Q
5 SETUP AND PROCEDURES BEFORE OPERATION
(4) Confirming the operation status
(a) Method using GX Developer
Read the following axis monitor data with the monitor function (Buffer
memory batch).
Buffer memory address
Axis monitor data
Monitor details
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7 Axis 8
Md. 1 Current feed value
Monitor the current position.
70
71
170
171
270
271
370
371
470
471
570
571
670
671
770
771
Md. 3 Current speed
Monitor the current speed.
74
75
174
175
274
275
374
375
474
475
574
575
674
675
774
775
Md. 4 Axis operation status
Monitor the operation status "2: JOG Operation"
of the axis.
76
176
276
376
476
576
676
776
Md. 5 Axis error code
Monitor the error occurrence definition.
77
177
277
377
477
577
677
777
For more information on the monitor details, refer to "Section 4.6 List of monitor data".
(Example) Operation status of Axis 1
<GX Developer display screen>
(b) Method using GX Configurator-PT
Monitor the "current feed value", "current speed", "axis operation status"
and "axis error code" on the "Monitor/Test screen".
(For details, refer to "Section 6.6 Monitor/test".)
(Example) Operation monitor of Axis 1 (Axis #1 Monitor/Test)
<GX Configurator-PT display screen>