13 - 10 13 - 10
MELSEC-Q
13 TROUBLESHOOTING
Related buffer memory address
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7 Axis 8
Setting range
Remedy
20
120
220
320
420
520
620
720
OPR. 1 OPR method
0: Near-point dog method
1: Stopper 1
2: Stopper 2, 3: Stopper 3
4: Count 1, 5: Count 2
21
121
221
321
421
521
621
721
OPR. 2 OPR direction
0: Forward direction
1: Reverse direction
Change the setting to within the setting
range and turn the PLC READY signal
(Y0) from OFF to ON.
24
25
124
125
224
225
324
325
424
425
524
525
624
625
724
725
Change the setting to within the setting
range, to not more than " Pr. 5 Speed
limit value" and to not less than " Pr. 6
Bias speed at start", and turn the PLC
READY signal (Y0) from OFF to ON.
26
27
126
127
226
227
326
327
426
427
526
527
626
627
726
727
OPR. 4 OPR speed
OPR. 5 Creep speed
1 to 200000 (pulse/s)
Change the setting to within the setting
range, to not more than "OPR. 4 OPR
speed" and to not less than " Pr. 6 Bias
speed at start", and turn the PLC READY
signal (Y0) from OFF to ON.
28
128
228
328
428
528
628
728
29
129
229
329
429
529
629
729
OPR. 6 ACC/DEC time at OPR
OPR. 7 DEC/STOP time at OPR
0 to 32767 (ms)
30
31
130
131
230
231
330
331
430
431
530
531
630
631
730
731
OPR. 8 Setting for the movement
amount after near-point dog ON
0 to 2147483647 (pulse/s)
13
113
213
313
413
513
613
713
Pr. 10 Stop mode during path control
0: Position match stop
1: Deceleration stop
Change the setting to within the setting
range and turn the PLC READY signal
(Y0) from OFF to ON.