3 - 9 3 - 9
MELSEC-Q
3 SPECIFICATIONS AND FUNCTIONS
3.4.2 Signal layout for external device connection connector
The specifications of the connector section, which is the input/output interface for the
QD70 and external device, are shown below.
The signal layout for the QD70 external device connection connector is shown.
QD70P4
CON1
RUN
ERR.
AX2
AX1
AX4
AX3
QD70P4
QD70P8
CON2
RUN
ERR.
AX6
AX5
AX8
AX7
CON1
AX2
AX1
AX4
AX3
QD70P8
CON 2 (for Axes 5 to 8)
CON 1 (for Axes 1 to 4)
Pin layout
Pin No.
Signal name
Pin No.
Signal name
Pin No.
Signal name
Pin No.
Signal name
B20
PG06 COM
1
A20
PG08 COM
1
B20
PG02 COM
1
A20
PG04 COM
1
B19
PG06
A19
PG08
B19
PG02
A19
PG04
B18
PG05 COM
1
A18
PG07 COM
1
B18
PG01 COM
1
A18
PG03 COM
1
B17
PG05
A17
PG07
B17
PG01
A17
PG03
B16
CLEAR6
COM
2
A16
CLEAR8
COM
2
B16
CLEAR2
COM
2
A16
CLEAR4
COM
2
B15
CLEAR6
A15
CLEAR8
B15
CLEAR2
A15
CLEAR4
B14
CLEAR5
COM
2
A14
CLEAR7
COM
2
B14
CLEAR1
COM
2
A14
CLEAR3
COM
2
B13
CLEAR5
A13
CLEAR7
B13
CLEAR1
A13
CLEAR3
B12
CHG6
A12
CHG8
B12
CHG2
A12
CHG4
B11
CHG5
A11
CHG7
B11
CHG1
A11
CHG3
B10
DOG6
A10
DOG8
B10
DOG2
A10
DOG4
B9
DOG5
A9
DOG7
B9
DOG1
A9
DOG3
B8
COM 5-6
3
A8
COM 7-8
3
B8
COM 1-2
3
A8
COM 3-4
3
B7
PULSE F6
A7
PULSE F8
B7
PULSE F2
A7
PULSE F4
B6
PULSE
COM6
4
A6
PULSE
COM8
4
B6
PULSE
COM2
4
A6
PULSE
COM4
4
B5
PULSE R6
A5
PULSE R8
B5
PULSE R2
A5
PULSE R4
B4
PULSE F5
A4
PULSE F7
B4
PULSE F1
A4
PULSE F3
B3
PULSE
COM5
4
A3
PULSE
COM7
4
B3
PULSE
COM1
4
A3
PULSE
COM3
4
B2
PULSE R5
A2
PULSE R7
B2
PULSE R1
A2
PULSE R3
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
B1
Vacant
A1
Vacant
B1
+24V
5
A1
+24G
5
1: Common for PG0 . (Axis No. 1 to 8 goes into ).
2: Common for CLEAR . (Axis No. 1 to 8 goes into ).
3: Common for DOG , CHG .(Axis No. 1 to 8 goes into ).
4: Common for PULSE F , PULSE R . (Axis No. 1 to 8 goes into ).
5: The external power source (24VDC) should be connected in order to output a command pulse.
(When outputing a command pulse of axis 5 to 8, the external power source (24VDC) should be connected to A1 and B1 of the
connector CON1 (for axis 1 to 4 use).)
Summary of Contents for GX Configurator-PT
Page 13: ...MEMO SECTION 1...
Page 127: ...7 20 7 20 MELSEC Q 7 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO...
Page 129: ...MEMO SECTION 2...