4 - 21 4 - 21
MELSEC-Q
4 DATA USED FOR POSITIONING CONTROL
4.5 List of positioning data
Before explaining the positioning data setting items Da. 1 to Da. 7 , the configuration
of the positioning data will be shown below.
The positioning data stored in the QD70 buffer memory has the following type of
configuration.
²‚
P
890
891
892
894
895
898
893
896
897
899
10
²‚
P
880
881
882
884
885
888
883
886
887
889
9
²‚
P
820
821
822
824
825
828
823
826
827
829
3
²‚
P
810
811
812
814
815
818
813
816
817
819
2
²‚
P
Da. 1 Operation pattern
Da. 2 Control method
800
801
802
804
805
808
803
806
807
809
Positioning data No. 1
Ax
is
1
²‚
P
1199
10
²‚
P
1189
9
²‚
P
1129
3
²‚
P
1119
2
²‚
P
1109
1190
1191
1192
1194
1195
1198
1193
1196
1197
1180
1181
1182
1184
1185
1188
1183
1186
1187
1120
1121
1122
1124
1125
1128
1123
1126
1127
1110
1111
1112
1114
1115
1118
1113
1116
1117
1100
1101
1102
1104
1105
1108
1103
1106
1107
²‚
P
999
10
²‚
P
989
9
²‚
P
929
3
²‚
P
919
2
²‚
P
909
990
991
992
994
995
998
993
996
997
980
981
982
984
985
988
983
986
987
920
921
922
924
925
928
923
926
927
910
911
912
914
915
918
913
916
917
900
901
902
904
905
908
903
906
907
²‚
P
1099
10
²‚
P
1089
9
²‚
P
1029
3
²‚
P
1019
2
²‚
P
1009
1090
1091
1092
1094
1095
1098
1093
1096
1097
1080
1081
1082
1084
1085
1088
1083
1086
1087
1020
1021
1022
1024
1025
1028
1023
1026
1027
1010
1011
1012
1014
1015
1018
1013
1016
1017
1000
1001
1002
1004
1005
1008
1003
1006
1007
Da. 3 ACC/DEC time
Da. 4 DEC/STOP time
Da. 5 Command speed
Da. 7 Dwell time
Reserved (Cannot Be
Used)
Da. 6 Positioning
address/movement
amount
Buffer memory address
Ax
is
2
Da. 1 Operation pattern
Da. 2 Control method
Da. 3 ACC/DEC time
Da. 4 DEC/STOP time
Da. 5 Command speed
Da. 7 Dwell time
Reserved (Cannot Be
Used)
Da. 6 Positioning
address/movement
amount
Positioning data No. 1
Buffer memory address
Da. 1 Operation pattern
Da. 2 Control method
Positioning data No. 1
Ax
is
3
Da. 3 ACC/DEC time
Da. 4 DEC/STOP time
Da. 5 Command speed
Da. 7 Dwell time
Reserved (Cannot Be
Used)
Da. 6 Positioning
address/movement
amount
Buffer memory address
Da. 1 Operation pattern
Da. 2 Control method
Positioning data No. 1
Ax
is
4
Da. 3 ACC/DEC time
Da. 4 DEC/STOP time
Da. 5 Command speed
Da. 7 Dwell time
Reserved (Cannot Be
Used)
Da. 6 Positioning
address/movement
amount
Buffer memory address
: Write to Reserved (Cannot be used) is prohibited.
Summary of Contents for GX Configurator-PT