6 - 14 6 - 14
MELSEC-Q
6 UTILITY PACKAGE (GX Configurator-PT)
[Explanation of items]
(1) Setting item list
Setting item
Error status
Warning status
Axis #1 Current Feed Value
Axis #1 Current Speed
Axis #1 Axis Operation Status
Axis #1 Axis Error Code
Axis #1 Axis Warning Code
Axis #1 Executing Positioning Data No.
to
Axis #n Current Feed Value
Axis #n Current Speed
Axis #n Axis Operation Status
Axis #n Axis Error Code
Axis #n Axis Warning Code
Axis #n Executing Positioning Data No.
n indicates the axis No.
QD70P4: 1 to 4 QD70P8: 1 to 8
(2) Contents of the screen display
Module side buffer
size
: Displays the size of the setting item buffer memory.
Module side transfer
word count
: Displays the number of words to transfer.
Transfer direction
: " " indicates that data at the PLC CPU side is written to
the buffer memory.
" " indicates that data is read from the buffer memory to
the PLC CPU side.
PLC side device
: Enter the device at the CPU module to be automatically
refreshed.
The devices that can be used include X, Y, M, L, B, T, C,
ST, D, W, R, and ZR. When using bit devices, X, Y, M, L
or B, set a number that can be divided by 16 points
(examples: X10, Y120, M16).
Also, buffer memory data is stored in 16-point portions
starting with the device number that has been set. For
example, if X10 is set, data will be stored to X10 through
X1F.
(3) Explanation of the command buttons
Make text file
Creates a file containing the displayed screen data in a text
file format.
End setup
Confirms the entry of set data and ends the operation.
Cancel
Cancels the set data and ends the operation.
POINTS
•
The auto refresh settings are stored in the intelligent module parameters. Once
the intelligent module parameters are written to the CPU module, they can be
enabled by turning the power OFF and then ON, or resetting the CPU module.
•
Auto refresh settings cannot be changed from the sequence program. However,
it is possible to add a process similar to auto refresh by using the FROM/TO
commands of the sequence program.