7 - 3 7 - 3
MELSEC-Q
7 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
7.2 List of devices used
In "Section 7.4 Positioning control program examples", the used devices are assigned
as indicated in the following table.
The I/O numbers for QD70 indicate those when QD70 is mounted in the 0-slot of the
main base.
If it is mounted in the slot other than the 0-slot of the main base, change the I/O
number to that for the position where QD70 was installed.
In addition, change the external inputs, internal relays and data resisters, according to
the system used.
(1) Inputs/outputs, external inputs, and internal relays of QD70
Device
Device
name
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7 Axis 8
Application
Details when ON
X0
Module READY signal
QD70 ready
X1
Axis error occurrence signal
Axis error occurring
X2
Axis warning occurrence signal Axis warning occurring
X8
X9
XA
XB
XC
XD
XE
XF
BUSY signal
BUSY (running)
X10
X11
X12
X13
X14
X15
X16
X17 Start complete signal
Start complete
Input
s
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F Positioning complete signal
Positioning control complete
Y0
PLC READY signal
PLC CPU ready
Y8
Y9
YA
YB
YC
YD
YE
YF
Positioning start signal
Start being requested
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17 Axis stop signal
Stop being requested
Inputs/
outputs
of
QD70
Out
put
s
Y18
Y19
Y1A
Y1B
Y1C
Y1D
Y1E
Y1F JOG start signal
JOG being started
X20
OPR request OFF command
OPR request OFF being
commanded
X21
Machine OPR control
command
Machine OPR control being
commanded
X22
Fast OPR control command
Fast OPR control being
commanded
X23
Positioning control start
command
Positioning control start being
commanded
X24
Speed-position switching
control command
Speed-position switching control
being commanded
X25
Speed-position switching
enable command
Speed-position switching enable
being commanded
X26
Speed-position switching
disable command
Speed-position switching disable
being commanded
X27
Positioning control start signal
command
Positioning control start signal
being commanded
X28
Forward run JOG command
Forward run JOG operation being
commanded
X29
Reverse run JOG command
Reverse run JOG operation being
commanded
X2A
Speed change command
Speed change being commanded
X2B
Restart command
Restart being commanded
X2C
Error reset command
Error reset being commanded
External
input
(command)
X2D
–
Stop command
Stop being commanded
M0
Parameter/OPR data setting
complete
Parameter/OPR data setting
complete
M1
OPR request OFF command
OPR request OFF being requested
M2
OPR request OFF command
pulse
OPR request OFF command given
M3
OPR request OFF command
storage
OPR request OFF command held
M4
Fast OPR control command
Fast OPR control being requested
M5
Fast OPR control command
storage
Fast OPR control command held
M6
Positioning control start
command pulse
Positioning control start command
given
M7
Positioning control start
command storage
Positioning control start command
held
M8
JOG operation flag
JOG operation being performed
M9
Speed change command pulse Speed change command given
M10
Speed change command
storage
Speed change command held
M11
Restart command pulse
Restart command given
M12
Restart command storage
Restart command held
M13
Axis 1 error occurrence flag
Axis 1 error occurring
M14
Error reset command pulse
Error reset command given
Internal
relay
M15
–
Stop command pulse
Stop command given