3 MAJOR POSITIONING CONTROL
3.2 Positioning Data Setting
93
3
■
Restrictions
In the following case, an error occurs and the positioning will not start. During the positioning control, the operation stops
immediately at the detection of the error.
• If the movement amount of each axis exceeds 1073741824 (= 2
30
) when 0: Composite speed is set in [Pr.20] Interpolation
speed specification method, Outside linear movement amount range (Error code: 1A15H) occurs at the start of the
positioning. (The maximum movement amount that can be set in [Da.6] Positioning address/movement amount is
1073741824 (= 2
30
).)
■
Positioning data to be set
To use the 3-axis linear interpolation control (INC linear 3), set the following positioning data.
: Always set,
: Set as required,
: Setting not required
For details on the settings, refer to the following.
• If Reference axis speed is used for the 3-axis linear interpolation control, set the major axis as the reference
axis. If the minor axis is set as the reference axis, the speed of the major axis cannot be suppressed with
[Pr.8] Speed limit value.
• For the combinations of the reference axis and interpolation axes, refer to the following.
Setting item
Setting requirement of
reference axis
Setting requirement of
interpolation axis
[Da.1]
Operation pattern
[Da.2]
Control method
(Set INC linear 3.)
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.5]
Axis to be interpolated
[Da.6]
Positioning address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time
[Da.10]
M code
[Da.27]
M code ON signal output timing
[Da.28]
ABS direction in degrees
[Da.29]
Interpolation speed specification method
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......