12 DATA USED FOR POSITIONING CONTROL
12.3 Basic Setting
417
12
[Pr.53] OP shift amount
Set the amount to shift (move) the OP from the stop position with machine OPR.
The OP shift function is used to compensate the OP position stopped with machine OPR.
If the OP position is physically limited due to the installation position of the near-point dog, use this function to compensate the
OP to an optimum position.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Setting range
The setting range depends on the setting of [Pr.1] Unit setting.
*1 When this buffer memory area is set with programs, a calculation is performed in the RD75 to convert a setting value to the value in
each unit. For setting this buffer memory area, take the value after the unit conversion into consideration.
■
Default value
The default value is 0 for all the axes.
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Pr.53] OP shift amount
84
234
384
534
85
235
385
535
Setting of [Pr.1] Unit setting
Setting value with engineering tools
Setting value with programs
0: mm
-214748364.8 to 214748364.7 (
m)
-2147483648 to 2147483647 (
10
-1
m)
1: inch
-21474.83648 to 21474.83647 (inch)
-2147483648 to 2147483647 (
10
-5
inches)
2: degree
-21474.83648 to 21474.83647 (degree)
-21474.83648 to 21474.83647 (
10
-5
degrees)
3: pulse
-2147483648 to 2147483647 (pulse)
-2147483648 to 2147483647 (pulse)
V
Zero signal
Near-point dog signal
Start point
Shift point
Shift point
Pr.44 OPR direction
Shift after deviation counter
clear is canceled.
When Pr.53 OP shift amount
is positive
When Pr.53 OP shift amount
is negative
Position
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......