422
12 DATA USED FOR POSITIONING CONTROL
12.4 Positioning Data
[Da.2] Control method
Set Control method for performing the positioning control. The following table lists the available control methods.
For the setting, refer to the following and check the assignment of this area.
Page 421 Configuration of positioning identifier
■
Buffer memory address
For the buffer memory address of this area, refer to the following.
■
Default value
The default value is 00H for all the axes.
Control method
Setting value
ABS1: 1-axis linear control (ABS)
01H
INC1: 1-axis linear control (INC)
02H
FEED1: 1-axis fixed-feed control
03H
VF1: 1-axis speed control (forward run)
04H
VR1: 1-axis speed control (reverse run)
05H
VPF: Speed-position switching control (forward run)
06H
VPR: Speed-position switching control (reverse run)
07H
PVF: Position-speed switching control (forward run)
08H
PVR: Position-speed switching control (reverse run)
09H
ABS2: 2-axis linear interpolation control (ABS)
0AH
INC2: 2-axis linear interpolation control (INC)
0BH
FEED2: Fixed-feed control by 2-axis linear interpolation
0CH
ABS
: Circular interpolation control with sub point specified (ABS)
0DH
INC
: Circular interpolation control with sub point specified (INC)
0EH
ABS .: Circular interpolation control with center point specified (ABS, CW)
0FH
ABS .: Circular interpolation control with center point specified (ABS, CCW)
10H
INC .: Circular interpolation control with center point specified (INC, CW)
11H
INC .: Circular interpolation control with center point specified (INC, CCW)
12H
VF2: 2-axis speed control (forward run)
13H
VR2: 2-axis speed control (reverse run)
14H
ABS3: 3-axis linear interpolation control (ABS)
15H
INC3: 3-axis linear interpolation control (INC)
16H
FEED3: Fixed-feed control by 3-axis linear interpolation
17H
VF3: 3-axis speed control (forward run)
18H
VR3: 3-axis speed control (reverse run)
19H
ABS4: 4-axis linear interpolation control (ABS)
1AH
INC4: 4-axis linear interpolation control (INC)
1BH
FEED4: Fixed-feed control by 4-axis linear interpolation
1CH
VF4: 4-axis speed control (forward run)
1DH
VR4: 4-axis speed control (reverse run)
1EH
ABSH
: Helical interpolation control with sub point specified (ABS)
20H
INCH
: Helical interpolation control with sub point specified (INC)
21H
ABSH .: Helical interpolation control with center point specified (ABS, CW)
22H
ABSH .: Helical interpolation control with center point specified (ABS, CCW)
23H
INCH .: Helical interpolation control with center point specified (INC, CW)
24H
INCH .: Helical interpolation control with center point specified (INC, CCW)
25H
NOP: NOP instruction
80H
POS: Current value change
81H
JUMP: JUMP instruction
82H
LOOP: Beginning of LOOP to LEND processing
83H
LEND: End of LOOP to LEND processing
84H
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......