520
14 TROUBLESHOOTING
14.3 Error and Warning Details
Error code classification
Error storage
If a moderate error or a minor error has occurred, Error detection signal turns on, and the corresponding error code is stored
in the following buffer memory address of [Md.23] Axis error No. Every time an error occurs, [Md.23] Axis error No. is
overwritten with the latest error code.
If any of the following errors is detected, the error code is stored in [Md.23] Axis error No. of axis 1.
Error code: 1080H, 190AH, 1930H, 1931H, 1932H, 3001H, 3002H
Error level
Error code
Error type
Moderate error
2600H to 2619H
Error at inter-module synchronization
3000H to 3BFFH
H/W error
Minor error
17C0H to 17DFH
Module extension parameter file error
1800H to 185FH
Error at interrupt function setting range check
1860H to 18BFH
Dedicated instruction error
18C0H to 18FFH
Error at inter-module synchronization
1900H to 193FH
Error common to positioning control
1940H to 197FH
Error at OPR or absolute position restoration
1980H to 198FH
Error in manual control
1990H to 19EFH
Error in positioning operation
19F0H to 19FFH
Block start data setting error
1A00H to 1A0FH
Condition data setting error
1A10H to 1A5FH
Positioning data setting error
1A60H to 1A9FH
Error at basic parameter setting range check
1AA0H to 1AFFH
Error at detailed parameter setting range check
1B00H to 1B3FH
Error at OPR parameter setting range check
1B40H to 1B9FH
Error at extension/system parameter setting range check
Axis No.
Error detection signal
Buffer memory address ([Md.23] Axis error No.)
1
X8
806
2
X9
906
3
XA
1006
4
XB
1106
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......