296
7 CONTROL SUB FUNCTIONS
7.9 Other Functions
During uncompleted OPR operation setting function
During uncompleted OPR operation setting function is used to select the positioning control performed when OPR request
flag is on.
Control details
The following table shows the correspondence between positioning controls and the setting of [Pr.58] Setting of operation
during uncompleted OPR to show whether the positioning start can be performed or not for each control.
Control precautions
Before starting the positioning while 0: Do not execute the positioning control is specified, turn off OPR request flag
beforehand.
Setting method
To use the during uncompleted OPR operation setting function, write the following data into the RD75 using a program.
Positioning control
[Pr.58] Setting of operation during uncompleted OPR
0: Do not execute the positioning
control and OPR request flag is on
1: Execute the positioning control
and OPR request flag is on
• Machine OPR
• JOG operation
• Inching operation
• Manual pulse generator operation
• Current value change using the start No. for a current value
change (No.9003)
• 1-/2-/3-/4-axis speed control
Positioning start possible (can be
executed)
Positioning start possible (can be
executed)
• 1-axis linear control
• 2-/3-/4-axis linear interpolation control
• 1-/2-/3-/4-axis fixed-feed control
• 2-axis circular interpolation control (sub point specification/
center point specification)
• 3-axis helical interpolation control (sub point specification/center
point specification)
• Speed-position switching control (INC mode/ABS mode)
• Position-speed switching control
• Current value change using positioning data (No.1 to 600)
Positioning start not possible (cannot be
executed)
Start error at OPR completion (Error code:
19A6H)
Positioning start possible (can be
executed)
Setting item
Setting
value
Setting detail
Buffer memory address
Axis 1
Axis 2
Axis 3
Axis 4
[Pr.58]
Setting of operation during
uncompleted OPR
Set the operation during the OPR.
0: Do not execute the positioning control
1: Execute the positioning control
90
240
390
540
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......