7 CONTROL SUB FUNCTIONS
7.8 Function Related to Stop
269
7
7.8
Function Related to Stop
As the functions related to stop, Stop command processing for deceleration stop function, Continuous operation interrupt
function, and Step function are provided. Each function is executed by setting parameters or creating and writing a program.
Stop command processing for deceleration stop function
Stop command processing for deceleration stop function is provided to set the deceleration curve if a stop cause occurs
during the deceleration stop processing (including automatic deceleration).
This function is valid for both trapezoidal and S-curve acceleration/deceleration processing methods.
For details on the stop cause, refer to the following.
Stop command processing for deceleration stop function consists of the deceleration curve re-processing function and
deceleration curve continuation function.
Control details
The following shows the operation of the stop command processing for deceleration stop function.
■
Deceleration curve re-processing
A deceleration curve is re-processed starting from the speed at the stop cause occurrence to top, according to the set
deceleration time. If a stop cause occurs during the automatic deceleration of the position control, the deceleration stop
processing stops as soon as the target has reached the positioning address specified in the positioning data currently being
executed.
■
Deceleration curve continuation
The current deceleration curve is maintained after the occurrence of a stop cause. If a stop cause occurs during the automatic
deceleration of the position control, the deceleration stop processing may be completed before the target has reached the
positioning address specified in the positioning data currently being executed.
t
V
Stop cause
occurrence
Deceleration curve according
to set deceleration time
Deceleration curve when a stop
cause does not occur.
Immediate stop at the specified
positioning address
Deceleration stop processing
(automatic deceleration) start
V
t
Stop cause occurrence
Deceleration stop processing
(automatic deceleration) start
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......