328
9 PARAMETER SETTING
9.3 Module Extension Parameter
Block start data
Set the block start data number 0 to 4 for each axis.
Condition data
Set condition data for each block start data.
■
Setting method
Item
Setting range
Reference
Shape
• 0: Termination
• 1: Continue
Start data No.
1 to 600
Page 436 [Da.12] Start data No.
Special start instruction
• 00h: Normal start
• 01h: Condition start
• 02h: Wait start
• 03h: Simultaneous start
• 04h: FOR loop
• 05h: FOR condition
• 06h: NEXT start
Page 437 [Da.13] Special start instruction
Parameter
• 1 to 10
• 0 to 255
1.
Double-click "Condition data edit" in "Axis
Block start
data".
2.
Click the cell of the condition data number to be edited
and click the [Edit] button.
3.
Select settings of "Condition Operator" and "Condition
Identifier" from the pull-down menu.
4.
Set "Condition Data" according to the condition set in
step 3.
5.
Click the [OK] button.
6.
Click the [Close] button.
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......