9 PARAMETER SETTING
9.2 Module Parameters
321
9
Refresh settings
Configure the setting to transfer the values in the buffer memory of the RD75 to devices or module labels in the CPU module.
By configuring these refresh settings, reading the data by program is not needed.
Select the transfer destination from the following at "Target".
• Module label (
• Refresh data register (
Page 321 Refresh data register (RD))
• Specified device (
Module label
Transfer the setting of the buffer memory to the corresponding module label of each buffer memory area. Setting "Current
feed value" of the axis to be transferred to the module label to "Enable" sets all the items of the set axis to "Enable".
Refresh data register (RD)
Transfer the setting of the buffer memory to the refresh data register (RD) of the CPU module. Other transfer destinations are
automatically set by setting the refresh data register (RD) to which "Current feed value" of each axis is transferred.
Specified device
Transfer the setting of the buffer memory to the specified device of the CPU module. The device X, Y, M, L, B, D, W, R, ZR,
and RD can be specified. To use the bit device X, Y, M, L, or B, set a number which is divisible by 16 points (example: X10,
Y120, M16). The data in the buffer memory is stored in devices for 16 points from the set number.
Ex.
When X10 is set, data is stored in X10 to X1F.
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......