12 DATA USED FOR POSITIONING CONTROL
12.1 Types of Data
353
12
Manual control
: Always set,
: Set as required,
: Setting restricted
: Setting not required (Because this item is an irrelevant item, the set value is ignored. Set the value within the setting range,
such as the initial value.)
Positioning parameter
Manual pulse
generator operation
JOG operation
Inching operation
Basic parameter 1
[Pr.1] Unit setting
[Pr.2] No. of pulses per rotation
[Pr.3] Movement amount per rotation
[Pr.4] Unit magnification
[Pr.5] Pulse output mode
[Pr.6] Rotation direction setting
[Pr.7] Bias speed at start
[Pr.62] Electronic gear selection
Basic parameter 2
[Pr.8] Speed limit value
[Pr.9] Acceleration time 0
[Pr.10] Deceleration time 0
Detailed parameter 1
[Pr.11] Backlash compensation amount
[Pr.12] Software stroke limit upper limit value
[Pr.13] Software stroke limit lower limit value
[Pr.14] Software stroke limit selection
[Pr.15] Software stroke limit valid/invalid setting
[Pr.16] Command in-position width
[Pr.17] Torque limit setting value
[Pr.18] M code ON signal output timing
[Pr.19] Speed switching mode
[Pr.20] Interpolation speed specification method
[Pr.21] Current feed value during speed control
[Pr.22] Input signal logic selection
[Pr.23] Output signal logic selection
[Pr.24] Manual pulse generator input selection
Detailed parameter 1
[Pr.150] Speed-position function selection
Detailed parameter 2
[Pr.25] Acceleration time 1
[Pr.26] Acceleration time 2
[Pr.27] Acceleration time 3
[Pr.28] Deceleration time 1
[Pr.29] Deceleration time 2
[Pr.30] Deceleration time 3
[Pr.31] JOG speed limit value
[Pr.32] JOG operation acceleration time selection
[Pr.33] JOG operation deceleration time selection
[Pr.34] Acceleration/deceleration processing selection
[Pr.35] S-curve ratio
[Pr.36] Sudden stop deceleration time
[Pr.37] Stop group 1 sudden stop selection
[Pr.38] Stop group 2 sudden stop selection
[Pr.39] Stop group 3 sudden stop selection
[Pr.40] Positioning complete signal output time
[Pr.41] Allowable circular interpolation error width
[Pr.42] External command function selection
[Pr.82] Start adjustment time
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......