12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
475
12
[Cd.18] Continuous operation interrupt request
Set this area to interrupt continuous operation.
• The continuous operation is interrupted by setting 1: Interrupt continuous control or continuous path control for this area.
• After the continuous operation interruption is accepted, 0 is automatically stored. Storing 0 indicates the completion of the
continuous operation interruption.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0 for all the axes.
[Cd.19] OPR request flag OFF request
Set this area to request to forcibly turn off the OPR request flag with the program when the flag is on.
• The OPR request flag is turned off by setting 1: Turn off OPR request flag for this area.
• After the OPR request flag is turned off, 0 is automatically stored. Storing 0 indicates the completion of the OPR request
flag OFF request.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0 for all the axes.
[Cd.20] Manual pulse generator 1 pulse input magnification
Set the factor by which the number of pulses from the manual pulse generator is magnified.
• When the setting value is 0, the value is handled as 1.
• When the setting value is 10001 or greater, the value is handled as 10000.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Setting range
The setting range is 1 to 10000.
■
Default value
The default value is 1 for all the axes.
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.18] Continuous operation interrupt request
1520
1620
1720
1820
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.19] OPR request flag OFF request
1521
1621
1721
1821
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.20] Manual pulse generator 1 pulse input magnification
1522
1622
1722
1822
1523
1623
1723
1823
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......