14 TROUBLESHOOTING
14.3 Error and Warning Details
521
14
Warning type
Warnings include the ones that occur in each operation (positioning operation, manual pulse generator operation, and JOG
operation) and the ones that occur in the settings common to positioning control.
Warning classification
Warning storage
If a warning has occurred, the corresponding warning code is stored in the following buffer memory address of [Md.24] Axis
warning No.
If a warning has occurred in positioning operation, 1 is stored in the following buffer memory address of [Md.31] Status, Axis
warning detection (b9).
Warning code
Warning type
0900H to 093FH
Warning common to positioning control
0980H to 098FH
Warning in manual operation (JOG operation and manual pulse generator operation)
0990H to 09EFH
Warning in positioning operation
0A10H to 0A5FH
Warning at positioning data setting range check
09F0H to 09FFH
Block start data setting warning
0B00H to 0B02H
Extension parameter acquisition warning
Axis No.
Buffer memory address ([Md.24] Axis warning No.)
1
807
2
907
3
1007
4
1107
Axis No.
Buffer memory address ([Md.31] Status)
1
817
2
917
3
1017
4
1117
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......