5 MANUAL CONTROL
5.2 JOG Operation
183
5
Example 2
When both Forward run JOG start signal and Reverse run JOG start signal are turned on simultaneously for one axis,
Forward run JOG start signal is given priority. In this case, Reverse run JOG start signal is validated when BUSY signal of the
RD75 turns off. However, if the forward run JOG operation is stopped due to Stop signal or an axis error, the reverse run JOG
operation is not performed even if Reverse run JOG start signal is turned on.
Example 3
When JOG start signal is turned on again during the deceleration due to turning off of JOG start signal, the JOG operation is
performed from the point when JOG start signal is turned on.
OFF
ON
OFF
ON
OFF
ON
t
BUSY signal
[XC, XD, XE, XF]
Forward run JOG operation
Reverse run JOG start
signal is ignored.
Reverse run JOG operation
Forward run JOG start signal
[Y8, YA, YC, YE]
Reverse run JOG start signal
[Y9, YB, YD, YF]
OFF
ON
t
OFF
ON
BUSY signal
[XC, XD, XE, XF]
Forward run JOG operation
Forward run JOG start signal
[Y8, YA, YC, YE]
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......