554
APPENDICES
Appendix 3 How to Find Buffer Memory Addresses
When setting block start data using a program, determine buffer memory addresses using the following calculation formula
and set the addresses.
■
Calculation formula for [Da.11] Shape and [Da.12] Start data No.
Use the following calculation formula.
• 26000 + (1000
(Ax - 1)) + (200
M) + (P - 1)
For each variable, substitute a number following the description below.
Ex.
When the buffer memory address that satisfies the following conditions is determined
• Axis 3
• Start block No.2
• Block start data point: 40
26000 + (1000
(3 - 1)) + (200
2) + (40 - 1) = 28439
■
Calculation formula for [Da.13] Special start instruction and [Da.14] Parameter
Use the following calculation formula.
• 26050 + (1000
(Ax - 1)) + (200
M) + (P - 1)
For each variable, substitute a number following the description below.
Ex.
When the buffer memory address that satisfies the following conditions is determined
• Axis 2
• Start block No.1
• Block start data point: 25
26050 + (1000
(2 - 1)) + (200
1) + (25 - 1) = 27274
Item
Description
Ax
The axis number of the buffer memory address to be determined. Substitute a number from 1 to 4.
M
The start block No. of the buffer memory address to be determined. Substitute a number from 0 to 4.
P
The block start data point of the buffer memory address to be determined. Substitute a number from 1 to 50.
Item
Description
Ax
The axis number of the buffer memory address to be determined. Substitute a number from 1 to 4.
M
The start block No. of the buffer memory address to be determined. Substitute a number from 0 to 4.
P
The block start data point of the buffer memory address to be determined. Substitute a number from 1 to 50.
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......