202
6 INTER-MODULE SYNCHRONIZATION FUNCTION (SIMULTANEOUS START OF MULTIPLE MODULES)
6.1 Control in Pre-analysis Mode
6.1
Control in Pre-analysis Mode
This section describes the control of the inter-module synchronization function in the pre-analysis mode. In the pre-analysis
mode, positioning data can be analyzed in advance. Thus, pulse output can be started at the same timing of an inter-module
synchronization cycle immediately after a positioning start trigger is input without any regard to the analysis time of the
positioning data. This facilitates synchronization of the pulse output start timing among multiple modules. However, the
applicable positioning data Nos. are 1 to 600.
Starting method
After setting positioning data, enable the pre-analysis mode and input a start trigger signal to the simultaneous start-target
RD75s while their [Md.61] Analysis complete flag is 1: Analysis completed. Only Positioning start signal [Y10, Y11, Y12, Y13]
can be used as the start trigger. If a signal other than Positioning start signal [Y10, Y11, Y12, Y13] is used as the start trigger,
pulse output may not start simultaneously.
Control details
The control details are the same as those of the quick start. Read the quick start described in the following as the start with the
inter-module synchronization.
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......