4 ADVANCED POSITIONING CONTROL
4.2 Execution Procedure for Advanced Positioning Control
157
4
4.2
Execution Procedure for Advanced Positioning
Control
The advanced positioning control is performed using the following procedure.
• Five sets of Block start data (50 points) and Condition data (10 items) corresponding to No. 7000 to 7004
are set with a program.
• Five sets of data from 7000 to 7004 can also be set using an engineering tool. If an engineering tool is used
to set Block start data and Condition data corresponding to 7000 to 7004 and to write the data into the
RD75, 7000 to 7004 can be set in [Cd.3] Positioning start No. in STEP 4.
STEP 1
Preparation
Control start
Set for the major positioning control.
Control end
STEP 2
Set the block start data corresponding to each control.
( Da.11 to Da.14
× Required data amount
)
(
to
× Required data amount
)
STEP 3
Set condition data.
Da.15
Da.19
STEP 4
STEP 5
STEP 6
STEP 7
Control stop
Same procedure as the stop of major
positioning control
STEP 8
Monitor the advanced positioning control.
Control
monitoring
Create a program to set "7000*" in Cd.3 Positioning
start No. (control data setting)
Set the point No. of block start data to be started
(1 to 50) in Cd.4 Positioning starting point No.
Create a program to turn on Positioning start signal
using a positioning start command.
Write the programs created on STEP 4
to the CPU module.
Turn on the positioning start command of the axis
to be started.
The operation is stopped when the control is completed.
First prepare to execute the major
positioning control because the advanced
positioning control is the control to execute
each control (major positioning control) set
in the positioning data on the specified
conditions.
Up to 50 of block start data (1 to 50 points)
can be set.
Set the condition data to specify them
in the block start data. Up to 10 of condition
data can be set.
By specifying "7000", the RD75 recognizes
that the control is the advanced positioning
control using block start data.
Create a program to execute the advanced
positioning control.
Monitor using an engineering tool.
Same procedure as the start of major
positioning control
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......