METRODATA NetTESTER FAMILY USER MANUAL
76-02-107 Rev.A
Page 26 of 133
OFF
Half Duplex
Table 2.8 Bit-switch 5
2.3.5 Switch 6: Proxy Client
Switch 6 can be used to enable a client for the Metrodata Proxy protocol on the
WAN/Network port. This switch should be left in the default position.
ON
Proxy client mode disabled
OFF
Proxy client mode enabled
Table 2.9 Bit-switch 6
2.3.6 Switch 7: Zero Touch Configuration
Zero-Touch Configuration (ZTC) is enabled via switch 7. This switch should be left in
the default position.
ON
ZTC enabled
OFF
ZTC disabled
Table 2.10 Bit-switch 7
2.3.7 Switch 8: Cold-Start (Factory Default)
This bit-switch will return the unit to its factory default settings, modified according to
the settings of the other bit-switches, as described above.
ON
Normal Operation
OFF
Return the unit to Factory Defaults
Table 2.11 Bit-switch 8
Note
: Once the unit has restarted, the switch must be returned to the ON position,
otherwise any subsequent restart will result in another cold start.