METRODATA NetTESTER FAMILY USER MANUAL
76-02-107 Rev.A
Page 30 of 133
The default settings for the terminal port are shown below:
Baud Rate
19200
Data Bits
8
Parity
None
Stop Bits
1
Table 4.3 Default terminal port settings
4.2 Initial LAN Connection
The unit can always be accessed using a special fixed IP address via one specific
interfaces, allowing management via SSH, even directly following a cold-start.
(Telnet and HTTP are normally also available but may be disabled as a security
precaution on certain special product versions.)
See section 7.1.1 for more information.
4.3 Trouble-shooting
4.3.1 "Console Disabled"
Should the terminal display “Console Disabled” this indicates that the Zero Touch
Config (ZTC) option is enabled. To change the unit to normal boot mode, move bit-
switches 7 and 8 to the OFF position and power cycle. Once the terminal has
displayed the main setup menu, return switch 8 to the default ON position.