![Metrodata NetTESTER NT1003 User Manual Download Page 62](http://html1.mh-extra.com/html/metrodata/nettester-nt1003/nettester-nt1003_user-manual_1779476062.webp)
METRODATA NetTESTER FAMILY USER MANUAL
76-02-107 Rev.A
Page 62 of 133
Brief type information from the SFP module is displayed here. If no module is
present this will show
Not Fitted
. If type information cannot be read (usually
because of incorrect module programming),
Unknown
will show.
14.1.3.2 SFP details
Menu Tree: Main Set-Up /
S
ettings /
W
AN Port / S
F
P Details
SFP Info Interface: NET
--------
Dist- Tx Wave-
Status Vendor Part No. Type ance length
---------------------------------------------------------------------------
Good Metrodata P96W0850M030C02B 10G MM 300m 850nm
Diagnostics
-----------
Tx-Pwr Rx-Pwr Bias Temp Supply
(dBm) (dBm) (mA) (C) (V)
-------------------------------------------
Alrm Hi 2 0 12 85 3.70
Warn Hi 1 -1 10 80 3.60
Warn Lo -9 -13 2 -5 3.00
Alrm Lo -10 -14 1 -10 2.90
Value -3 -40 5 38 3.28
Status OK ALARM OK OK OK
<Esc> - exit, <Enter> - refresh
SFP modules include an EEPROM to identify the module capabilities and these may
be read using the SFP device details option. The information display is as shown
below:
SFP Info Interface: SFP
--------
Dist- Tx Wave-
Status Vendor Part No. Type ance length
---------------------------------------------------------------------------
Good Metrodata S12W1310S010C12B 1.25G SM 10km 1310nm
Diagnostics
-----------
Tx-Pwr Rx-Pwr Bias Temp Supply
(dBm) (dBm) (mA) (C) (V)
-------------------------------------------
Alrm Hi -1 0 20 85 3.60
Warn Hi -3 -2 15 80 3.50
Warn Lo -10 -15 1 0 3.10
Alrm Lo -12 -17 1 -5 3.00
Value -6 -28 3 25 3.28
Status OK ALARM OK OK OK
<Esc> - exit, <Enter> - refresh
14.1.3.3 Speed
Menu Tree: Main Set-Up /
S
ettings /
W
AN Port / sp
E
ed