METRODATA NetTESTER FAMILY USER MANUAL
76-02-107 Rev.A
Page 82 of 133
Disabled
The tester operates in single-test mode. Only one test may be
defined.
Sequential
Multiple tests may be defined, and they will run in sequence
(each starting immediately after the previous one finishes). See
section 14.2.6.12.
Concurrent
Multiple tests may be defined, and they will run concurrently (all
starting at the same time) where hardware resources permit.
Concurrent mode is available only on the NT10G05.
Independent
Multiple tests may be defined, and each can be started at any
time without affecting other tests that may be defined and/or
running. Note, however that the NT1003 and NT1005 do not
support multiple tests running concurrently.
14.2.5.2 Report Settings
Menu Tree: Main Set-Up /
T
esting /
S
AM Tester /
R
eport Settings
REPORT SETTINGS
report Header <menu>
report file Name nt1005_00c0810017e6.rep
14.2.5.2.1
Report Header
Menu Tree: Main Set-Up /
T
esting /
S
AM Tester /
R
eport Settings / report
H
eader
A user-defined header may be created that will be added to the top of every test
report. The header is configured line by line as shown:
REPORT HEADER
1st line ********************************
*******************
2nd line Metrodata Service Configuration Test
3rd line
4th line Customer: CustomerA
5th line Link: London-NewYork
6th line Tester: A.N.Engineer
7th line
8th line ********************************
*******************
Clear all text
Display header <display>
Once defined, it may be displayed for checking by selecting display screen.
14.2.5.2.1.1 Clear all text
Menu Tree: Main Set-Up /
T
esting /
S
AM Tester /
R
eport Settings / report
H
eader /
C
lear all text
Select this option to clear the entire header.
14.2.5.2.1.2 Display Header